Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 127
Filtrar
1.
BMJ Open Respir Res ; 11(1)2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38609180

RESUMO

BACKGROUND: Recent studies have suggested elevated blood eosinophils are independent predictors of response to corticosteroid therapy in patients with acute exacerbation of chronic obstructive pulmonary disease (AECOPD). Smoking status has been shown to affect corticosteroid response. Whether the association between high blood eosinophils and corticosteroid treatment failure is modified by smoking has not been fully investigated so far. OBJECTIVES: This study aimed to assess whether the association between high blood eosinophils and corticosteroid treatment failure is modified by smoking. METHODS: We included 3402 inpatients with AECOPD treated with corticosteroids at Beijing Chao-Yang Hospital from July 2013 to June 2021. Blood eosinophil counts were measured within 24 hours of admission. An eosinophil percentage ≥2% was considered as high eosinophilic. Smokers in this study were defined as current or former smokers. Treatment failure was defined as a worsening of AECOPD that led to adverse clinical outcomes or required further treatment or an extended hospital stay or hospitalisation following the exacerbation. Multivariate-adjusted logistic models were used to estimate the OR and 95% CI associated with treatment failure. RESULTS: There were 958 (28.2%) treatment failure events occurring. Patients with high eosinophils had a lower risk of treatment failure (OR 0.74, 95% CI 0.63 to 0.87) than patients with low eosinophils. Compared with never smoking and low eosinophilic group, the ORs for treatment failure were 0.70 (95% CI 0.52 to 0.96) for never smoking and high eosinophilic group, 0.82 (95% CI 0.64 to 1.05) for smoking and low eosinophilic group and 0.62 (95% CI 0.47 to 0.81) for smoking and high eosinophilic group. Furthermore, there was no significant interaction between eosinophils and smoking status in relation to treatment failure (p for interaction=0.73). Similar results were obtained from multiple secondary outcomes and subgroup analyses. CONCLUSION: Elevated blood eosinophils are associated with a lower rate of corticosteroid treatment failure, regardless of smoking status. Smoking does not modify the association between blood eosinophil level and corticosteroid treatment failure among inpatients with AECOPD.


Assuntos
Eosinófilos , Doença Pulmonar Obstrutiva Crônica , Humanos , Pacientes Internados , Fumar/epidemiologia , Corticosteroides/uso terapêutico , Doença Pulmonar Obstrutiva Crônica/tratamento farmacológico , Falha de Tratamento
2.
Angew Chem Int Ed Engl ; : e202405357, 2024 Apr 29.
Artigo em Inglês | MEDLINE | ID: mdl-38682802

RESUMO

The rapid growth of flexible quasi-solid-state thermocells (TECs) provides a fresh way forward for wearable electronics. However, their insufficient mechanical strength and power output still hinder their further applications. This work demonstrates a one-stone-two-birds strategy to synergistically enhance the mechanical and thermoelectrochemical properties of the [Fe(CN)6]3-/4--based TECs. By introducing multiple non-covalent interactions via betaine zwitterions, the mechanical strength of the conventional brittle gelatin hydrogel electrolytes is substantially improved from 50 to 440 kPa, with a high stretchability approaching 250%. Meanwhile, the betaine zwitterions strongly affect the solvation structure of [Fe(CN)6]3- ions, thus enlarging the entropy difference and raising the thermoelectrochemical Seebeck coefficient from 1.47 to 2.2 mV K-1. The resultant quasi-solid-state TECs exhibit a superior normalized output power density of 0.48 mW m-2 K-2, showing a notable improvement in overall performance compared to their counterparts without zwitterion regulation. In addition, the intrinsic thermo-reversible property allows the TECs to repeatedly self-recover through sol-gel transformations, ensuring reliable energy output and even recycling of TECs in case of extreme mechanical damages. An energy-autonomous smart glove consisting of eighteen individual TECs is further designed, which can simultaneously monitor the temperature of different positions of any touched object, demonstrating high potential in wearable applications.

3.
J Inflamm Res ; 17: 1511-1526, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38476472

RESUMO

Purpose: Patients with acute exacerbation of chronic obstructive pulmonary disease (AECOPD) exhibit heterogeneous responses to corticosteroid treatment. We aimed to determine whether combining eosinophil levels with other routine clinical indicators can enhance the predictability of corticosteroid treatment outcomes and to come up with a scoring system. Patients and Methods: Consecutive patients admitted with AECOPD receiving corticosteroid treatment between July 2013 and March 2022 at Beijing Chao-Yang Hospital were retrospectively analyzed. Data on patients' demographics, smoking status, hospitalization for AECOPD in the previous year, comorbidities, blood laboratory tests, in-hospital treatment and clinical outcomes were collected. Least absolute shrinkage and selection operator (LASSO) regression and backward logistic regression were used for predictor selection, and predictive nomograms were developed. The discrimination and calibration of the nomograms were assessed using the area under the receiver operating curve (AUC) and calibration plots. Internal validation was performed using the 500-bootstrap method, and clinical utility was evaluated using decision curve analysis (DCA). Results: Among the 3254 patients included, 804 (24.7%) had treatment failure. A nomogram of eosinophils, platelets, C-reactive protein (CRP), low density lipoprotein cholesterol, prognostic nutritional index (PNI), hospitalization for AECOPD in the previous year, ischemic heart diseases and chronic hepatic disease was developed to predict treatment failure for patients with a smoking history. For patients without a smoking history, a nomogram of CRP, PNI, ischemic heart diseases and chronic hepatic disease was developed. Although the AUCs of these two nomograms were only 0.644 and 0.647 respectively, they were significantly superior to predictions based solely on blood eosinophil levels. Conclusion: We developed easy-to-use comprehensive nomograms utilizing readily available clinical biomarkers related to inflammation, nutrition and immunity, offering modestly enhanced predictive value for treatment outcomes in corticosteroid-treated patients with AECOPD. Further investigations into novel biomarkers and additional patient data are imperative to optimize the predictive performance.

4.
Nanomicro Lett ; 16(1): 151, 2024 Mar 11.
Artigo em Inglês | MEDLINE | ID: mdl-38466453

RESUMO

Despite notable progress in thermoelectric (TE) materials and devices, developing TE aerogels with high-temperature resistance, superior TE performance and excellent elasticity to enable self-powered high-temperature monitoring/warning in industrial and wearable applications remains a great challenge. Herein, a highly elastic, flame-retardant and high-temperature-resistant TE aerogel, made of poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate)/single-walled carbon nanotube (PEDOT:PSS/SWCNT) composites, has been fabricated, displaying attractive compression-induced power factor enhancement. The as-fabricated sensors with the aerogel can achieve accurately pressure stimuli detection and wide temperature range monitoring. Subsequently, a flexible TE generator is assembled, consisting of 25 aerogels connected in series, capable of delivering a maximum output power of 400 µW when subjected to a temperature difference of 300 K. This demonstrates its outstanding high-temperature heat harvesting capability and promising application prospects for real-time temperature monitoring on industrial high-temperature pipelines. Moreover, the designed self-powered wearable sensing glove can realize precise wide-range temperature detection, high-temperature warning and accurate recognition of human hand gestures. The aerogel-based intelligent wearable sensing system developed for firefighters demonstrates the desired self-powered and highly sensitive high-temperature fire warning capability. Benefitting from these desirable properties, the elastic and high-temperature-resistant aerogels present various promising applications including self-powered high-temperature monitoring, industrial overheat warning, waste heat energy recycling and even wearable healthcare.

5.
Mater Horiz ; 11(7): 1679-1688, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38305351

RESUMO

Due to the prevalence of electronic devices, intelligent sensors have attracted much interest for the detecting and providing alarms with respect to indoor electrical safety. Nonetheless, how to effectively identify various indoor electrical safety hazards remains a challenge. In this study, we fabricated single-walled carbon nanotube/poly(3-hexylthiophene-2,5-diyl) (SWCNT/P3HT) composites with exceptional bifunctional thermoelectric and photoelectric responses. Through synergy of the thermo-/photoelectric effects, the composites yielded greatly enhanced output voltages compared with the use of thermoelectric effects alone. Interestingly, modes of heat transfer can be effectively distinguished using the nominal Seebeck coefficients. Based on the remarkable output voltages and deviations in the nominal Seebeck coefficients, we developed indoor intelligent sensors capable of effectively identifying and monitoring diverse indoor electrical conditions, including electrical overheating, fire, and air conditioning flow. This pioneering investigation proposes a novel avenue for designing intelligent sensors that can recognize heat transfer modes and hence effectively monitor indoor electrical safety hazards.

6.
Front Med (Lausanne) ; 11: 1351589, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38384409

RESUMO

Background: Silicosis shows an increasing trend with the development of new industries. However, the potential biomarkers for predicting the disease severity are lacking. A novel inflammatory marker, the systemic immune-inflammation Index (SII), has not been studied in silicosis. Methods: In this retrospective study, we used data from a big database platform of a tertiary general hospital in Beijing, which was established based on the electronic medical records of the hospital. The clinical data of adult patients diagnosed with silicosis at the Department of Occupational Medicine and Toxicology from 2013 to 2022 were collected. The data extracted from the database were in de-identified form. Only patients with a first diagnosis of silicosis and without conditions that might affect the parameters of routine blood tests were included in the analysis. Analyses were performed to assess the relationship between SII and the advanced stage of silicosis. Results: A total of 246 participants were included in the study. Most of the patients were exposed to silica particles during excavation and digging (n = 149, 60.6%). SII level was significantly higher in patients with advanced stages of silicosis. A multivariate logistic regression analysis revealed that a higher SII level was associated with the advanced stage of silicosis [odds ratio (OR) = 1.002; 95% confidence interval (CI): 1.000-1.003, p < 0.001] after adjusting for all covariates. The best cutoff value of SII was 444.1. The results of the subgroup analysis also showed a significant correlation between SII level over 444.1 and the advanced stage of silicosis in groups stratified by gender, history of smoking, and duration of silica exposure. Moreover, our results showed a significant but weak negative correlation between the level of SII and some lung function parameters in silicosis. Conclusion: Higher SII is associated with the advanced stage of silicosis and impaired lung function. More long-term, large-scale studies are needed to confirm these findings.

7.
JMIR Public Health Surveill ; 10: e53170, 2024 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-38386387

RESUMO

BACKGROUND: Maternal smoking during pregnancy (MSDP) is a known risk factor for offspring developing chronic obstructive pulmonary disease (COPD), but the underlying mechanism remains unclear. OBJECTIVE: This study aimed to explore whether the increased COPD risk associated with MSDP could be attributed to tobacco dependence (TD). METHODS: This case-control study used data from the nationwide cross-sectional China Pulmonary Health study, with controls matched for age, sex, and smoking status. TD was defined as smoking within 30 minutes of waking, and the severity of TD was assessed using the Fagerstrom Test for Nicotine Dependence. COPD was diagnosed when the ratio of forced expiratory volume in 1 second to forced vital capacity was <0.7 in a postbronchodilator pulmonary function test according to the 2017 Global Initiative for Chronic Obstructive Lung Disease criteria. Logistic regression was used to examine the correlation between MSDP and COPD, adjusting for age, sex, BMI, educational attainment, place of residence, ethnic background, occupation, childhood passive smoking, residential fine particulate matter, history of childhood pneumonia or bronchitis, average annual household income, and medical history (coronary heart disease, hypertension, and diabetes). Mediation analysis examined TD as a potential mediator in the link between MSDP and COPD risk. The significance of the indirect effect was assessed through 1000 iterations of the "bootstrap" method. RESULTS: The study included 5943 participants (2991 with COPD and 2952 controls). Mothers of the COPD group had higher pregnancy smoking rates (COPD: n=305, 10.20%; controls: n=211, 7.10%; P<.001). TD was more prevalent in the COPD group (COPD: n=582, 40.40%; controls: n=478, 33.90%; P<.001). After adjusting for covariates, MSDP had a significant effect on COPD (ß=.097; P<.001). There was an association between MSDP and TD (ß=.074; P<.001) as well as between TD and COPD (ß=.048; P=.007). Mediation analysis of TD in the MSDP-COPD association showed significant direct and indirect effects (direct: ß=.094; P<.001 and indirect: ß=.004; P=.03). The indirect effect remains present in the smoking population (direct: ß=.120; P<.001 and indirect: ß=.002; P=.03). CONCLUSIONS: This study highlighted the potential association between MSDP and the risk of COPD in offspring, revealing the mediating role of TD in this association. These findings contribute to a deeper understanding of the impact of prenatal tobacco exposure on lung health, laying the groundwork for the development of relevant prevention and treatment strategies.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Tabagismo , Feminino , Gravidez , Humanos , Estudos de Casos e Controles , Estudos Transversais , Fumar , Doença Pulmonar Obstrutiva Crônica/epidemiologia , Doença Pulmonar Obstrutiva Crônica/etiologia
8.
BMC Public Health ; 24(1): 65, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166920

RESUMO

BACKGROUND AND AIMS: Tobacco use has posed a tremendous public health problem for China. The Chinese government has taken great efforts to curb the tobacco epidemic. However, the existing smoking cessation services available in China are underused and have some limitations. Our research team intends to develop a smartphone smoking cessation application (SSC APP) and integrate it with the existing smoking cessation services. This study aims to assess the efficacy of the SSC APP developed by our research team through a randomized controlled trial (RCT). METHODS: Current smokers who are motivated to quit within 1 month (n = 1000) will be recruited both online and offline, and all potential participants will register and complete the prescreening assessment online. Participants will be randomly assigned to either the intervention group (receiving the SSC APP and a self-help smoking cessation manual) or the control group (receiving a self-help smoking cessation manual only) using a block randomization method. This study will be a two-arm, single-blind, parallel-group RCT. Participants will be followed up after enrollment through online questionnaires or by phone call. The primary outcome is self-reported 6-month continuous abstinence. The main secondary outcomes include self-reported 7-day point-prevalence abstinence at each follow-up; self-reported 3-month continuous abstinence; reduction in the number of cigarettes smoked per day; and the number of recent quit attempts. DISCUSSION: If this SSC APP proves to be effective, it could be integrated with the existing smoking cessation services and further facilitate smoking cessation at the population level in China. TRIAL REGISTRATION: Chinese Clinical Trial Registry: ChiCTR2200062097, Registered July 22, 2022.


Assuntos
Aplicativos Móveis , Abandono do Hábito de Fumar , Humanos , Abandono do Hábito de Fumar/métodos , Fumantes , Comportamentos Relacionados com a Saúde , Terapia Comportamental , Ensaios Clínicos Controlados Aleatórios como Assunto , Produtos do Tabaco
10.
Technol Health Care ; 32(2): 989-996, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-37545281

RESUMO

BACKGROUND: With rapid progression, severe illness and high fatality rate, sepsis has become an acute and critical condition that seriously threatens human life and health. OBJECTIVE: To detect miR-210 and miR-494 expression in patients with sepsis and their relationship with severity and prognosis. METHODS: A total of 165 sepsis patients participated, including 105 patients with septic non-shock and 60 patients with septic shock. 53 sepsis patients died in 28 days, and 112 patients survived. The clinical information of all sepsis patients was retrospectively searched and reviewed. Based on the status of 28-day survival, they were categorized into survival group and death group. The expression levels in each group were compared on the first, third and seventh day. The ROC curve was applied to know the expression level of plasma miR-210 and miR-494 to predict the death. RESULTS: The two miRNAs expression of the septic shock group were significantly higher than that in sepsis non-shock group on the first, third and seventh day (all were P< 0.05). The ROC curve found that the AUC combined to predict the death on the third day was the largest, which was 0.925 (95%CI: 0.864-0.983). The sensitivity and specificity were 94.6% and 86.3%, respectively. CONCLUSION: The increased expression levels of plasma miR-210 and miR-494 are closely relevant to the severity and prognosis of sepsis patients. Combining the two items on the third day can predict the death of sepsis patients.


Assuntos
MicroRNAs , Sepse , Choque Séptico , Humanos , Choque Séptico/genética , Estudos Retrospectivos , Sepse/genética , Sepse/diagnóstico , Prognóstico , Curva ROC
11.
Tob Induc Dis ; 21: 150, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38026501

RESUMO

INTRODUCTION: Traditional Chinese medicine (TCM) may have special advantages in facilitating smoking cessation, but consensus on effectiveness is lacking. We aim to comprehensively review, update, and refine current evidence on TCM effectiveness and safety. METHODS: Nine databases were searched from their inception up to 28 February 2023. Systematic reviews (SRs) and meta-analysis of TCM for smoking cessation were identified and retrieved. Additional databases and hand searches of RCTs from included SRs were performed for data pooling. Cochrane ROB tools and AMSTAR-2 were used to evaluate the methodological quality of RCTs and SRs, respectively. RCT data are presented as relative risks (RR) or mean differences (MD) with 95% confidence intervals (CI) using RevMan 5.4. RESULTS: Thirteen SRs involving 265 studies with 33081 participants were included. Among these 265 studies, 157 were duplicates (58.36%) and 52 were non-RCTs (19.62%). Combined with the remaining 56 RCTs identified through hand searches, 88 RCTs involving 12434 participants were finally included for data synthesis. All the SRs focused on acupoint stimulation, and the majority were of low or very low quality. The methodological quality of RCTs was either unclear or high risk. For continuous abstinence rate, TCM external interventions were better than placebo in 6 months to 1 year (RR=1.60; 95% CI: 1.14-2.25; I2=27%; n=5533 participants). Compared with placebo, TCM external application was effective in reducing nicotine withdrawal symptoms, and the effect was gradually stable and obvious in the fourth week (MD= -4.46; 95% CI: -5.43 - -3.49; n=165 participants). Twelve RCTs reported adverse events as outcome indicators for safety evaluation, and no serious adverse events occurred. CONCLUSIONS: Despite the methodological limitations of the original studies, our review suggests that TCM intervention shows potential effectiveness on the continuous abstinence rate. Extending the intervention time can enhance the effect of TCM on nicotine withdrawal symptoms. Referred to adverse events, more data for safety evaluation are required.

12.
Chron Respir Dis ; 20: 14799731231215093, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37949435

RESUMO

OBJECTIVE: The Asthma Quality of Life Questionnaire (AQLQ) and COPD assessment test (CAT) are used to assess the health status of asthma and chronic obstructive pulmonary disease (COPD), respectively. However, whether these questionnaires are appropriate in patients with asthma-COPD overlap (ACO) has not been reported. This study aimed to evaluate the performance of the AQLQ and CAT in subjects with ACO. METHODS: Subjects were enrolled from two previously described observational studies in Beijing, China. ACO was defined by a consensus definition from a roundtable discussion. All subjects completed the AQLQ, CAT, St George's Respiratory Questionnaire (SGRQ), pulmonary function tests, and the Asthma Control Questionnaire (ACQ)-5. Cross-sectional construct validity was evaluated by correlating the AQLQ and CAT with SGRQ score and other measures of asthma and COPD severity. RESULTS: 147 subjects with ACO were recruited. There were floor effects on non-respiratory components of the CAT, and ceiling effects on emotion domains of the AQLQ. Both questionnaires were significantly correlated with ACQ-5 score but were not correlated with FEV1% predicted or FVC% predicted. The AQLQ and CAT were strongly correlated with SGRQ score (r = -0.657 and r = 0.623, respectively). Multivariable linear regression analysis showed that the AQLQ (standardized ß-coefficient = -0.449, p < .001) had a stronger association with SGRQ score compared with CAT (standardized ß-coefficient = 0.211, p = .023). DISCUSSION: The AQLQ and CAT were both valid for assessing the health-related quality of life in subjects with ACO, but the AQLQ performed better than CAT.


Assuntos
Asma , Doença Pulmonar Obstrutiva Crônica , Humanos , Qualidade de Vida , Estudos Transversais , Asma/psicologia , Inquéritos e Questionários
13.
Environ Pollut ; 338: 122665, 2023 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-37806428

RESUMO

The co-occurrence of fine particulate matter (PM2.5) and ozone (O3) pollution during the warm season has become a growing public health concern. The interaction between PM2.5 and O3 and its contribution to disease burden associated with co-pollution has not been thoroughly examined. We collected data on hospital admissions for respiratory diseases from a city-wide hospital discharge database in Beijing between 2013 and 2019. City-wide 24-h mean PM2.5 and daily maximum 8-h mean O3 were averaged from 35 monitoring stations across Beijing. Conditional Poisson regression was employed to estimate the interaction between warm-season PM2.5 and O3 on respiratory admissions. A model incorporating a tensor product term was used to fit the non-linear interaction and estimate the number of respiratory admissions attributable to PM2.5 and O3 pollution. From January 18, 2013 to December 31, 2019, 1,191,308 respiratory admissions were recorded. We observed multiplicative interactions between warm-season PM2.5 and O3 on upper respiratory infections (P = 0.004), pneumonia (P = 0.002), chronic obstructive pulmonary disease (P = 0.041), and total respiratory disease (P < 0.001). PM2.5-O3 co-pollution during warm season exhibited a super-additive effect on respiratory admissions, with a relative excess risk due to interaction of 1.65% (95%CI: 0.46%-2.84%). There was a non-linear pattern of the synergistic effect between PM2.5 and O3 on respiratory admissions. Based on the World Health Organization global air quality guidelines, 12,421 respiratory admissions would be reduced if both daily PM2.5 and O3 concentrations had not exceeded the target (PM2.5 15 µg/m3, O3 100 µg/m3). The number of respiratory admissions attributable to either PM2.5 or O3 pollution decreased by 48.7% from 2013 to 2019. Prioritizing O3 control during the warm season is a cost-effective strategy for Beijing. These findings underscore the significance of concurrently addressing both PM2.5 pollution and O3 pollution during the warm season to alleviate the burden of respiratory diseases.


Assuntos
Poluentes Atmosféricos , Poluição do Ar , Transtornos Respiratórios , Doenças Respiratórias , Humanos , Poluentes Atmosféricos/análise , Poluição do Ar/análise , Material Particulado/análise , Transtornos Respiratórios/epidemiologia , Doenças Respiratórias/epidemiologia , Hospitais
14.
Digit Health ; 9: 20552076231208553, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37868155

RESUMO

Objective: This study sought to develop a WeChat mini-program for smoking cessation behavioral interventions (named the WQ mini-program) and evaluate its usability, acceptability, and preliminary efficacy among Chinese smokers. Methods: The WQ mini-program was designed based on behavioral change theories and clinical practice guidelines, and clinical smoking cessation experts participated in the development process. Fifty Chinese smokers and five software experts were involved in a single-arm trial. Smokers were asked to use the WQ mini-program at least once a day for 4 weeks and to complete a weekly online follow-up questionnaire. Software experts were asked to complete an online follow-up questionnaire after using all functions of the WQ mini-program. Primary outcomes were usability and acceptability of and satisfaction with the mini-program tested by the System Usability Scale (SUS) and the Mobile App Rating Scale (MARS). Self-reported 7-day point prevalence abstinence (PPA) was used to evaluate its preliminary efficacy for smoking cessation. Optimization suggestions for the mini-program were collected from all participants through an open-ended question at the last follow-up and were analyzed by thematic analysis. Results: The mean SUS and MARS total scores for the WQ mini-program as evaluated by smokers were 82.1 ± 13.8 and 84.5 ± 3.3 and by software experts were 4.21 ± 0.32 and 4.27 ± 0.15, respectively. Most smokers reported being willing to recommend this mini-program to other smokers (85.4%) and would continue to use it (95.8%). The mean satisfaction score for the mini-program was 4.23 ± 0.69 (out of 5 points) among smokers. Self-reported 7-day PPA among smokers at the 4-week follow-up was 50% (25/50). Conclusions: This study demonstrated that the WQ mini-program would be a feasible and potentially effective method to encourage Chinese smokers to quit smoking. However, future research is needed to confirm its efficacy through a randomized controlled trial.

15.
Sci Bull (Beijing) ; 68(24): 3261-3277, 2023 Dec 30.
Artigo em Inglês | MEDLINE | ID: mdl-37722927

RESUMO

Historically, fire disasters have killed numerous human lives, and caused tremendous property loss. Fire warning systems play a vital role in predicting fire risks, and are strongly desired to effectively prevent the disaster occurrence and significantly reduce the loss. Among the developed fire warning systems, thermoelectrics (TEs) and thermocells (TECs)-based fire warning materials are extremely important and indispensable in future research, owing to their unique capability of direct conversion between heat and electricity. Here, we present this review of the recent progress of TEs and TECs in fire warning field. Firstly, a brief introduction of existing fire warning systems is provided, including the mechanisms and features of various types. Then, the mechanisms of electronic TE (eTE), ionic TE (iTE) and TEC are elucidated. Next, the basic principles for the material preparation and device fabrication are discussed in their dimension sequence. Subsequently, some important advances or examples of TE fire warnings are highlighted in details. Finally, the challenges and prospects are outlooked.

16.
Int J Chron Obstruct Pulmon Dis ; 18: 1783-1802, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37608836

RESUMO

Purpose: To discover potential inflammatory biomarkers, which can compare favorably with traditional biomarkers, and their best cut-offs at first admission to predict clinical outcomes (short-term and long-term) and the risk of readmission among acute exacerbations of chronic obstructive pulmonary disease (AECOPD) patients. Patients and Methods: Novel inflammatory biomarkers (such as the neutrophil-lymphocyte ratio [NLR], platelet-lymphocyte ratio [PLR], etc.) were compared with traditional biomarkers by Pearson's correlation test. Logistic regression analysis and receiver operating characteristic (ROC) curves were applied to judge the accuracy of these novel biomarkers to predict in-hospital mortality. Results: Surviving AECOPD patients had lower NLR, PLR, and lymphocyte-to-monocyte ratios than non-survival patients (all P < 0.001). According to Pearson's correlation test, there was a linear correlation between novel and traditional biomarkers (all P < 0.05). In terms of a single biomarker, the AUC value of NLR was the largest, which was not inferior to C-reactive protein (Z-P = 0.064), and superior to erythrocyte sedimentation rate (Z-P = 0.002) and other novel single inflammatory biomarkers (all Z-P < 0.05). The mortality of patients with NLR ≥ 4.43 was 2.308-fold higher than that of patients with NLR < 4.43. After dividing patients into a higher or lower NLR group, pooled results showed that patients with NLR ≥ 4.43 had a higher rate of treatment failure, intensive care unit admission, longer hospital length of stay, one-year mortality after the index hospitalization, and overall mortality than patients with NLR < 4.43 (all P < 0.001). Patients with NLR ≥ 4.43 were associated with higher and earlier first readmission due to AECOPD than patients with lower NLR. Conclusion: NLR was the best to forecast the clinical prognosis and readmission risk among AECOPD patients, which was not inferior to CRP, and the best cut-off value of NLR was 4.43.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Humanos , Pequim , Estudos Retrospectivos , Doença Pulmonar Obstrutiva Crônica/diagnóstico , Doença Pulmonar Obstrutiva Crônica/terapia , Biomarcadores , Proteína C-Reativa
17.
Nanomicro Lett ; 15(1): 196, 2023 Aug 11.
Artigo em Inglês | MEDLINE | ID: mdl-37566154

RESUMO

The evolution of wearable technology has prompted the need for adaptive, self-healable, and energy-autonomous energy devices. This study innovatively addresses this challenge by introducing an MXene-boosted hydrogel electrolyte, which expedites the assembly process of flexible thermocell (TEC) arrays and thus circumvents the complicated fabrication of typical wearable electronics. Our findings underscore the hydrogel electrolyte's superior thermoelectrochemical performance under substantial deformations and repeated self-healing cycles. The resulting hydrogel-based TEC yields a maximum power output of 1032.1 nW under the ΔT of 20 K when being stretched to 500% for 1000 cycles, corresponding to 80% of its initial state; meanwhile, it sustains 1179.1 nW under the ΔT of 20 K even after 60 cut-healing cycles, approximately 92% of its initial state. The as-assembled TEC array exhibits device-level self-healing capability and high adaptability to human body. It is readily applied for touch-based encrypted communication where distinct voltage signals can be converted into alphabet letters; it is also employed as a self-powered sensor to in-situ monitor a variety of body motions for complex human actions. The swift assembly approach, combined with the versatile functionality of the TEC device, paves the way for future advancements in wearable electronics targeting at fitness monitoring and human-machine interfaces.

18.
J Inflamm Res ; 16: 3233-3243, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37555013

RESUMO

Purpose: Blood eosinophil is a promising biomarker for phenotyping patients with acute exacerbation of COPD (AECOPD). We aimed to evaluate the prognostic value of eosinophil on short- and long-term outcomes stratified by corticosteroid treatment among AECOPD inpatients. Patients and Methods: In this retrospective cohort study, we included patients hospitalized for AECOPD from July 2013 to June 2021 in Beijing, China. Clinical data were collected from electronic medical records. The blood eosinophil count was measured within 24h after admission. Eosinophilic AECOPD was defined as having an eosinophil percentage ≥ 2%. The study outcomes were length of stay (LOS), treatment failure, and AECOPD readmission risk within 3 years of discharge. Multivariable models were used to analyze the associations between blood eosinophil count and outcomes stratified by corticosteroid treatment during hospitalization. Results: A total of 2406 AECOPD patients were included. The median LOS of AECOPD patients was 10 (interquartile range: 8-14) days. The eosinophil percentage was negatively associated with LOS (P-trend=0.014). Compared with the non-eosinophilic AECOPD group, the eosinophilic group had a 58% lower risk of treatment failure (OR=0.42, 95% CI: 0.20-0.89) in patients treated with systemic corticosteroids, but no association was observed in those treated with inhaled corticosteroids (ICS) only (OR=0.95, 95% CI: 0.60-1.52). The eosinophilic group had an increased risk of 90-day re-admission in patients treated with ICS only (HR=1.51, 95% CI: 1.00-2.29), but not in patients treated with systemic corticosteroids during hospitalization (HR=0.67, 95% CI: 0.39-1.15). No statistically significant results were found for 180-day, 1-year, or 3-year readmission risk. Conclusion: Elevated blood eosinophils in AECOPD were associated with shorter length of stay and improved response to treatment with systemic corticosteroids, but not inhaled corticosteroids. Our study suggested that a therapeutic approach of using systemic corticosteroid may benefit patients present with eosinophilic AECOPD.

19.
China CDC Wkly ; 5(21): 464-468, 2023 May 26.
Artigo em Inglês | MEDLINE | ID: mdl-37405266

RESUMO

What is already known on this topic?: Mobile health interventions have been demonstrated to be effective in aiding smoking cessation among smokers. Nevertheless, research on this topic remains limited in China. What is added by this report?: Following two months of utilizing the services of a comprehensive mobile health (mHealth)-based modality ("Way to Quit" modality) which integrated three online interventions through the WeChat application, 29.1% of participating smokers successfully quit smoking. Participants who used a greater number of online services were more likely to cease smoking. All services were scored highly for satisfaction among smokers. What are the implications for public health practice?: This study presents a practical and feasible method to assist Chinese smokers in quitting smoking. The results of this research suggest a promising direction for enhancing the accessibility and utilization of smoking cessation services. Additionally, these findings serve as a critical reference for addressing the obstacles faced by smoking cessation services in China.

20.
BMC Pulm Med ; 23(1): 214, 2023 Jun 17.
Artigo em Inglês | MEDLINE | ID: mdl-37330486

RESUMO

BACKGROUND: The association between periodontitis and post-bronchodilator lung function is unclear. We aimed to determine the associations between symptoms of severe periodontitis (SSP) and post-bronchodilator lung function in the Chinese population. METHODS: A cross-sectional study (China Pulmonary Health study) was conducted from 2012 to 2015 in a large Chinese nationally representative sample of 49,202 participants aged 20-89 years. Data on demographic characteristics and periodontal symptoms of participants were collected by questionnaire. Participants who had at least one of the two severe symptoms (tooth mobility and natural tooth loss) in the past year were defined to have SSP, which was set as one variable for analyses. Post-bronchodilator lung function data including forced expiratory volume in 1 s (FEV1) and forced vital capacity (FVC) were collected by spirometry. RESULTS: The values of post-FEV1, post-FVC and post-FEV1/FVC of the participants with SSP were all significantly lower than the participants without SSP (all p < 0.001). SSP were significantly associated with post-FEV1/FVC < 0.7 (p < 0.001). In the multiple regression analyses, SSP were still negatively associated with post-FEV1(b = -0.04, 95%CI (-0.05 -0.03), p < 0.001), post-FEV1/FVC (b = -0.45, 95%CI (-0.63, -0.28), p < 0.001) and significantly associated with post-FEV1/FVC < 0.7 (OR = 1.08, 95%CI 1.01-1.16, p = 0.03) after full adjustment for potential confounders. CONCLUSIONS: Our data suggest that SSP were negatively associated with post-bronchodilator lung function in the Chinese population. Longitudinal cohort studies are needed to confirm these associations in the future.


Assuntos
Doença Pulmonar Obstrutiva Crônica , Humanos , Broncodilatadores/uso terapêutico , Estudos Transversais , Volume Expiratório Forçado , Capacidade Vital , Espirometria/métodos , Pulmão
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA